Niki t34 ambulatory syringe driver

Use of t34 syringe driver hospital palliative care service. The t34 is a battery powered pump that drives a syringe. Designed specifically for microinfusion environments, the t341ml ambulatory syringe pump from cme is now the perfect partner for small volume drug infusions. The t34 ambulatory syringe pump has a three point syringe detection feature, each with displacement alarm and syringe recognition of commonly used syringe brands 2 to 50ml. Ambulatory syringe pumps are portable batteryoperated devices for delivering medication by continuous subcutaneous infusion csci over a given time period usually 24 hours. Safe practice in syringe pump management nursing times.

T34 deliver syringe infusion anywhere provide complete smalldose infusion therapy safely and economically wherever your patients receive care. Consumables please contact mkinley member of our customer support team on for more information about administration sets for the t the t34 ambulatory syringe pump has a three point syringe detection feature, each with displacement alarm and syringe recognition of commonly used syringe brands 2 to 50ml. Volume detection and automatic calculation of infusion rate in mlhr. Procedure for the use of mckinley t34 syringe driver to deliver a continuous subcutaneous infusion in palliative care for adults key points 1.

They are useful when small volumes of drugs need to be infused at a slow rate dougherty and lister, 2011, and their compact design enables patients to move around and. Community palliative care service aims to provide palliative care to patients in their homes and residences during a lifelimiting illness. The following instructions are relevant where the niki t34 has been preprogrammed to a fixed duration of 24 hours and has the program lock function on day 1. T34 syringe driver instruction video for oxfordshire youtube. T34 compact ambulatory syringe mini infusion pump driver mckinley t34 compact ambulatory syringe mini infusion pump driver administration. Provide complete smalldose infusion therapy safely and economically wherever your patients receive care. The syringe driver used across asph is the mckinley t34 ambulatory syringe pump. Mckinley niki t34 syringe pump ebay image is loading mckinleynikit34syringepump. A syringe driver is a portable battery powered device that administers medication subcutaneously over a chosen period of time. Supports multiple languages over 20 languages available to. The goals of care are to provide comprehensive support for the patient, their family and other carers through impeccable assessment and management of physical, psychological and spiritual needs. District health boards of new zealand dhbnz has recommended the ad ambulatory syringe driver, distributed by cardinal health, as the preferred replacement syringe driver in palliative care in new zealand dhbnz 2009. Cpcre centre for palliative care research and education. The system may not meet all performance specifications if operated outside of the following conditions.

A copy of the syringe driver instruction manual is to be available in the treatment room for rns to access while the syringe driver is in use. The niki t34 syringe driver is contained within a locked box. Cme medical t34 ambulatory syringe driver safer by design. T34 takes a 1050ml syringe and t34l 1060ml syringe any brand. Initially the preferred replacement option was the ad ambulatory syringe driver, however, the company involved was unable to supply and support these drivers and a further decision was made so that by 30 june, 2011, the niki t34 syringe driver was used exclusively.

The use of the niki t34 syringe pump via the subcutaneous route is. Syringe driver using a niki t34 for continuous subcutaneous infusion csci procedure includes procedure for labelling syringe with subcut medication label. Mike day everything about concrete recommended for you. Prepare medication in relevant syringe and attach infusion line and catheter do not attach infusion line to the patient, yet. The t34 syringe pump is a small, lightweight ambulatory infusion pump which offers flexibility and reliability. Initial and subsequent setting up of the syringe driver must be undertaken by registered nurses competent in the use of the mckinley t34 ambulatory syringe driver. The size and weight of the t34 makes it ideal for ambulatory use in a hospital or alternate site.

See details cme ambulatory syringe driver niki t34 nikit34 works. Syringe earcollar sensor detects correct loading of syringe collar 3. Niki t34 infusion syringe pump progress healthcare. September 2018 page 4 of 31 palliative care department 2. Niki t34 syringe pump instruction manual ref 90ss edition june 2008 0473. Please select a capability in order to start your service request. Read and understand this manual and all warnings before operating the t34 syringe pump. The t34 is the safety standard in ambulatory syringe pumps and is designed to maximise safe and simple administration of medication.

How to form, pour, and stamp a concrete patio slab duration. Plunger sensor detects correct loading of syringe plunger 4. Full alarm protection helps prevent events and instill confidence in patients. The niki t34 syringe pump safely provides a complete smalldose infusion therapy safely wherever your residents receive care automatically detects syringe size and brand fully programmable flow rates and infusion times lightweight and portable, the pump can be mounted to an iv pole software allows.

Nikki pump syringe drivers for windows syringe drivers can be used either shortterm or longterm, for patients who are ambulatory and those who are confined to bed. The t34 ambulatory syringe pump from cme contains many features of larger syringe pumps in. Only the healthcare clinician medical or nursing is able to open the box. The t34 syringe driver is designed for infusion of medications or fluids requiring. Care of the syringe driver once in use the safety aspects of the syringe driver what to do and where to get advice if niki syringe syringe driver is not niki syringe properly, or symptoms are not controlled, e. The niki t34 syringe driver is a small, portable battery operated, programmable, ambulatory syringe pump that delivers the contents of a 2 to 50ml syringe over. The t34 is a small, lightweight, robust, battery powered, ambulatory syringe pump designed to deliver the contents of a 2 to 50ml syringe over a specified duration. Caesarea niki t34 syringe pump mckinley deliver syringe infusion anywhere provide complete smalldose infusion therapy safely and economically wherever your patients receive care. T34 ambulatory syringe pump administration set 1x20.

T34 ambulatory syringe pump administration set care shop. The t34 ambulatory syringe pump kit includes everything you need to start your first infusion, purchase one today and ensure you have access to the leading ambulatory syringe driver for palliative care. T341ml is a unique accurate syringe pump that enables small volume syringe capability starting with 1ml syringes. Powered by a 9v 6lr61 type battery syringe recognition of commonly used syringe brands 2 to 50ml. Cme infusion pumps provide a complete range of infusion onboard any air or ground vehicle. Subcutaneous infusion device education printable documents. The niki t34 syringe driver is a small, portable battery operated, programmable, ambulatory syringe pump that delivers the contents of a 2 to 50ml syringe over a specified duration of time or at a given rate in millilitres per hour mlhr.

After the healthcare clinician loads the prepares syringe of medication as per orders, the niki t 34 syringe driver will calculate the infusion rate. Niki t34 syringe driver for fixed 24 hour infusions. The nikki pump is an ingenious system that is able to deliver a continuous infusion of medications via the subcutaneous route, for symptom. Identify the common sites used for syringe drivers and areas to avoid. Page 20 for alarm information page 21 for trouble shooting guide if you wish to do some refresher training prior to commencing the syringe driver. Barrel clamp arm detects syringe sizewidth of barrel 2.

Warnings advise of circumstances that could result in injury or death to the useroperator or circumstances that could result in damage to the device. The t34 ambulatory syringe pump from cme contains many features of larger syringe pumps in one highly compact, lightweight design. Cme ambulatory syringe driver niki t34 nikit34 works. It is designed to administer your medications slowly over a 24hour period. When and how to use a syringe driver in palliative. The administration set is for use with the t34 ambulatory syringe pump. Guidelines for subcutaneous infusion device management in palliative care. Management of the mckinley t34 subcutaneous ambulatory.

Cme ambulatory syringe driver niki t34 nikit34 works for. The t34 pump is easy to use for inpatient and outpatient applications. Niki t34 syringe driver vedefar discover our products. Nswlhd niki t34 syringe driver user guide western nsw phn. Management of subcutaneous infusion devices in palliative. Printable subcutaneous infusion education documents. A syringe containing medication is attached to the driver, which pushes the plunger forward at a controlled rate. T34 ambulatory syringe pump is a lightweight, compact and fully ambulatory syringe pump with motor driven linear actuator, pulsed motion.

This also make the t34l pumps the ideal pump for clinical trials. Syringe drivers t34 and t34l ambulatory syringe drivers. The medicines are given via thin tubing, attached to a small needle placed in the fatty layer beneath the skin in. We have filters, extensions, burette sets, blood sets, iv ports, iv sets, needless iv ports, syringe and volumetric pumps, securement devices and stopcocks, connectors and sets. T34 compatibility information scottish palliative care guidelines website guidelines for the use of the t34 ambulatory syringe pump by cme medical for adults in palliative care pdf 2. Niki pump t34 syringe driver infusion observation chart updated 20042018 niki t34 syringe driver infusion observation chart medication 24 hour dose checked stock strength mgml required volume mls date commenced. Guidelines for syringe driver management in palliative. The t34 syringe driver is designed for infusion of medications or fluids requiring continuous or intermittent delivery at precisely controlled infusion rates through all clinically acceptable routes of administration including intravenous, subcutaneous, percutaneous, intra. Palliative care community and oral health education. Niki t34 syringe pump king edward memorial hospital. Explain the reasons for the use of syringe drivers. Niki t34 syringe driver download automatically detects the syringe brand using 3 independent sensor system.

The only other commercially available and viable alternatives. The t34 is the safety standard in ambulatory syringe pumps offering a comprehensive range of features designed to maximise safe and simple administration. Cme medical t34 ambulatory syringe driver safer by. Aims to enable staff to use t34 ambulatory syringe drivers safely and effectively objectives. Once mixed, syringes should be observed for any signs. The t34 is an ambulatory syringe pump designed to deliver the contents of a 2 to 50ml syringe over a specified duration, or at a given rate in milliliters per hour. These guidelines are intended for use by all nurses within ashford and st peters hospitals nhs foundation trust asph involved with setting up, monitoring and caring for patients with a subcutaneous ambulatory syringe driver in situ. Things you might want to know about your driver or pump.

Claire britton, specialist nurse practitioner from sobell houses community team, demonstrates how to set up the t34 syringe driver. This is because the niki t34 syringe driver simplifies administration by detecting the syringe size and volume of medicine, and sets the rate to deliver the infusion over the required time period, e. Guidelines for setting up and changing the mckinley t34 syringe driver for children receiving palliative care. Syringe pump infusion pump lambda vitfit, precise and highpressure syringe pumps, syringe driver duration.